Mitsubishi Electric C80 Series Connection And Set Up Manual page 230

Hide thumbs Also See for C80 Series:
Table of Contents

Advertisement

C80 Series Connection and Setup Manual
14 Setting the Position Detection System
(Note 1) To change just the basic machine coordinate zero point, set "#0 Absolute posn set" and "#2 Zero-P", and then
turn the power OFF and ON.
(Note 2) If pressing against the machine end is attempted without passing the grip point once after turning the power
ON, the operation message "Not passed on grid" will appear. Return to a point before the last grid, and then
repeat from step of pressing against the machine end stopper.
(Note 3) If the first grid point is covered by the grid mask (#2028 grmask) as a result of return to the electric basic
position, the axis stops at the next grid point.
Note that zero-point shift amount (#2027 G28sft) is invalid.
199
IB-1501452-C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents