17 Data Backup and Restoration
The data backup and the data restoration of the PLC CPU and the CNC CPU will be performed by the backup/restoration
function of the GOT2000 series.
The backup data will be saved in an SD card or a USB memory connected to the GOT2000 series.
The target data for the backup/restoration are as follows:
( ○ : Targeted , ×: Not targeted)
Data outline
System file
Parameters
Machining program
Machine tool builder macro program
MDI program
Tool offset data
Tool all data files
Workpiece offset data
Common variable
Safety parameters(*1)
Safety ladders(*1)
APLC load module
System data
(*1)
When the parameter "#1481 Enable S-safety" (Enable smart safety observation) is set to "1", and when
restoring the safety parameters and the safety ladders, release the safety password with the parameter
"#51013 SF_PSWD". If the safety password is not released, these files will not be restored (the restoration will
be skipped).
When the safety password of the CNC does not match that of the target file for the restoration even though the
safety password is released, an error will occur during the restoration.
(*2)
This file is valid when the specification of program memory capacity is 1000kB[2560m] or 2000kB[5120m].
(Note 1) Make sure to complete the editing of the machining program or the data setting operation before performing
the backup/restoration.
(Note 2) When the parameter "#1391 User level protect" (Enable Data protection by user's level) is set to "1", release
the protect before operating the backup/restoration.
IB-1501452-C
File name
SYSPRM.BIN
ALL.PRM
ALL.PRG
ALL2.PRG (*2)
MACROALL.BIN
MDIALL.PRG
TOOL.OFS
TOOLALL.DAT
WORK.OFS
COMMON.VAR
SAFEPARA.BIN
SAFEPLC1.LAD
SAFEPLC2.LAD
APLC.BIN
SRAM.BIN