ABB X Series G5 Startup Manual page 30

Flow computers and remote controllers
Hide thumbs Also See for X Series G5:
Table of Contents

Advertisement

7.
Secure the solar panel cable to the pipe:
a.
Do not wrap the cable around the mounting pipe. Run the solar
panel cable along the mounting pipe and use nylon tie wraps to
secure the cable.
b.
Gather excess cable and attach it to the mounting pipe using a
nylon tie wrap.
8.
Install the cable and cable gland in the enclosure:
a.
Remove a shipping plug from the left side of the flow computer
enclosure.
b.
Open the hinged door on the flow computer and visually locate
the CHRG terminal block (J5 on the XFC, J17 on the XRC).
c.
Remove the cable nut from the cable conduit elbow and insert
the cable and conduit ends through the access hole in the
enclosure.
d.
Pull the cable into the enclosure leaving enough cable to reach
the CHRG terminal block (J5 on the XFC, J17 on the XRC).
e.
Replace the cable nut on the cord and conduit end inside of the
enclosure and screw the nut onto the conduit end finger-tight.
f.
Position the conduit elbow so that moisture will not follow the
cable and seep into the gland. Tighten the cable nut.
g.
Using a small slotted screwdriver, remove the terminal
connector from the CHRG terminal block (J5 on the XFC, J17 on
the XRC).
9.
Wire the solar panel cable to the unattached CHRG connector:
NOTICE – Equipment damage. Do not insert the connector into
the CHRG terminal block (J5 on the XFC, J17 on the XRC) until
instructed to do so in section
a.
On the solar panel cable, trim the wire cover ends back ¼ inch
(6.35 mm) if necessary.
b.
Loosen the terminal connector screws for pins 1 and 2.
c.
Insert each solar panel cable wire, as identified by the cable
label
(+ or -), into the corresponding CHRG pin (+ or -), as shown in
the figure below. Gently tighten the terminal connector screws.
2 8 | XSE RI ES G5 STA RT UP GUI DE | 21 0 60 0 1MNAA
WARNING – Bodily injury. Install the electrical wiring
according to requirements for the area classification. Refer to
the certification drawing indicated on the device's name tag,
and national and local electrical codes.
6.5: Connect the
charger.

Advertisement