security passcode and keep it safe as it will be required to establish
a connection from Wi-Fi clients.
IMPORTANT NOTE: If planning to leave the XFC or XRC with the
security switch on, make sure to test the passcode before leaving
the field. Turn off the onboard security switch to reset to factory
defaults remotely if the new passcode is lost. Note that resetting
Wi-Fi to factory defaults resets all Wi-Fi parameters, not only the
passcode.
Click Send to save the new passcode.
8.
Click Yes to confirm. A message displays indicating that the passcode
9.
change is successful.
10. Take note of the IP address (default: 192.168.1.1) as it is required to
establish connection using PCCU.
IMPORTANT NOTE: The default IP address assigned to the XFC
and XRC for Wi-Fi connections is not the same as the default IP
address assigned to Ethernet. When configuring PCCU for either
type of connection, make sure to use the correct address.
11. Test that the Wi-Fi enabled XFC or XRC is available and establish
connection. This test can be performed from the same laptop or PC
used during this configuration if it is enabled for Wi-Fi.
On the laptop, click the Windows Start button and go to Control
a.
Panel>Network and Internet>Network and Sharing
Center>Connect to a network.
b.
View wireless networks detected and verify that the network ID
assigned to the XFC or XRC displays.
Select Network ID and click Connect.
c.
Figure 10-8: Network connections
2 1 0 60 01M NAA | X SER IE S G 5 S TART UP G UI DE | 6 3