Wall-Mount Installation - ABB X Series G5 Startup Manual

Flow computers and remote controllers
Hide thumbs Also See for X Series G5:
Table of Contents

Advertisement

3.
Level the mounting pipe:
a.
Level and center the pipe and saddle on the top of the meter
run. Tighten the saddle-mounting U-bolt.
b.
Level the pipe so that the pipe is perpendicular to the meter
run using the saddle leveling bolts (if available) on the
mounting saddle.
4.
Tighten the saddle-mounting U-bolt as tight as possible to avoid
vibration-related issues.
5.
Install the XFC or XRC mounting brackets to the back of the
enclosure using the pipe mount instructions supplied in the mounting
kit.
6.
Attach the enclosure to the mounting pipe:
a.
Hold the enclosure in place against the mounting pipe and
insert a U-bolt around the pipe and through the corresponding
holes on the upper mounting bracket.
b.
Add the flat washer and split washer onto the U-bolt, then
screw the nut onto the U-bolt.
c.
Repeat steps 6a and 6b for the second mounting bracket.
7.
Raise the XFC or XRC into position on the mounting pipe.
IMPORTANT NOTE: Position the XFC or XRC high enough to allow
some downward slope from the externally mounted manifold to
the tap valves.
8.
Secure the XFC in place by tightening the U-bolt nuts. This will help
to avoid vibration-related issues.
IMPORTANT NOTE: The enclosure mounting kit contains more
parts than needed for mounting the enclosure on a meter house
wall.

Wall-mount installation

IMPORTANT NOTE: Select a mounting location that allows for
easy access, is close to the tap valves, and complies with all
local and national codes.
IMPORTANT NOTE: Large enclosures are heavy and bulky. More
than one person may be required for installation.
2 1 0 60 01M NAA | XSER IE S G5 S TART UP G UI DE | 1 5