2.6 Connecting LD512H to Terminal Block
Follow the procedures below to connect a Loop Display Unit, LD512H, to a terminal
block.
(1) Remove the terminal block cover on the back of the unit, and wire an RS-485 cable.
(2) Connect the 24-V wires to pins 4, 5, and 6 on the terminal block.
Make sure of the polarities and the GND terminal.
(3) Upon completion of wiring, mount the terminal block cover on the terminal block.
• Confirm that the power terminal block or RS-485 terminal block has been correctly wired.
• Turning on the power with incorrect wiring may result in burning or electric shock.
6F8C1005
RS-485 signal line
RS-485 cable
Shielding wire
processed
Figure 2-7 Wiring of RS-485 Cable
DC24V
0V
GND(FG)
Figure 2-8 Power Wiring
2.6 Connecting LD512H to Terminal Block
Remove the terminal
block cover
TR+
①
TR −
②
③
④
⑤
⑥
Caution
2
77