MULTIPLE CONSOLE OPERATION-CCIS

General Description
This feature provides console operation where Attendant Consoles are installed in more than one node in
the CCIS network.
Station Application
Attendant Console
Programming
START
CM05
Assign a Unit number and Slot number to the
DLC blade.
NOTE 1:
NOTE 2:
CM10
Assign the DESKCON No. for the appropriate
Physical Port number.
NOTE 1:
NOTE 2:
A
DESCRIPTION
BLADE RESET
Attendant Consoles can only be
accommodated to Unit01.
A maximum of 2 Attendant Consoles
can be accommodated per DLC
blade (A maximum of 8 Attendant
Consoles can be accommodated in
system).
BLADE RESET
A blade reset is also required when
adding Attendant Consoles to the
existing DLC blade.
If the PGD(2)-U10 ADP is accom-
modated to the DLC blade (the
second data of CM13 Y=63 is set to
"0"), Attendant Consoles cannot be
accommodated to the same DLC
blade.
MULTIPLE CONSOLE OPERATION-CCIS
Y=0
(1)
XX ZZ
XX: 01: Unit No.
ZZ : 01-18: Slot No.
(2)
10: DLC blade
Y=00
(1)
XX YY ZZ: Physical Port No.
XX: 01: Unit No.
YY: 01-18: Slot No.
ZZ : 01-32: Circuit No.
(2)
E000-E007: DESKCON No.
1-200