Mitsubishi Electric MELSEC iQ-R Series User Manual page 112

Melsecnet/h network module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Item
Network Information
Other
Communication Status of
Station
each Station
Information
Data-Link Status of each
Station
Parameter Status of each
Station
CPU Operation Status of
each Station
CPU RUN Status of each
Station
Loop Status of each Station
Reversed Station
Designation of each Station
External Power Operation
Status of each Station
Each Station PLC Operation
Mode Status
Each Station Pairing Status
Each Station PLC System
Status
Each Station Network Type
Status
4 TROUBLESHOOTING
110
4.3 Checking the Network Status
Description
Indicates the same information as own station
information.
Indicates the baton pass status (transient
transmission availability).
Indicates the cyclic transmission status.
Indicates the parameter status of each station.
Indicates the operating status of the CPU module.
Enabled when the communication status of each
station is "Baton pass normal station".
Indicates the RUN/STOP status of the CPU
module.
Enabled when the communication status of each
station is "Baton pass normal station".
The reserved station is "".
Indicates the forward/reverse loop status.
Enabled only for normally operating stations in
'Baton pass status of each station'.
Indicates the reserved station setting status.
Indicates the external 24VDC power supply status
of the network module.
Enabled when the communication status of each
station is "Baton pass normal station".
Indicates the operation mode of the redundant
CPU.
For the items other than the redundant CPU,
"" is displayed.
Indicates the status of the pairing setting.
Displays the redundant CPU system status.
For the items other than the redundant CPU,
"" is displayed.
Displays the consistency between the network type
set for the control station and the network type set
for the normal station.
Displayed information
Page 106 Host Station Information
• Normal display: Baton pass normal station, reserved
station
• Reverse display: Baton pass faulty station
(Disconnection status)
• Normal display: Normal station, reserved station
• Reverse display: Faulty station (Data link not in
operation)
When each station is in the parameter communication
status
• Normal display: Parameter communication not in
progress, reserved station, unconnected station
• Reverse display: Parameter communication in progress
When each station is in the parameter error status
• Normal display: Parameters normal, reserved station,
unconnected station
• Reverse display: Parameter error
• Normal display: Normal CPU, reserved station,
unconnected station
• Reverse display: CPU error (Minor: Minor error, Severe:
Moderate error, Severe error)
• RUN: RUN, STEP-RUN
• STOP: STOP, PAUSE, ERROR, unconnected station
• : Reserved station
• Normal display: Normal, reserved station, unconnected
station
• Reverse display: Error
• Normal display: Non-reserved station
• Reverse display: Reserved station
• Normal display: 24VDC not input, MELSECNET/H
network module without a supply terminal
• Reverse display: 24VDC input
The following is indicated for the CPU status.
• Backup Mode
• Separate Mode
The following is indicated for the CPU status.
• No Pair
• Pair
The following is indicated for the CPU status.
• Control System
• Standby System
Normal display: Reserved station, communication faulty
station
Reverse display: Shown below
• Normal station set to MELSECNET/H mode or
MELSECNET/10 mode when the control station is in
MELSECNET/H extended mode
• Normal station set to MELSECNET/H extended mode
when the control station is in MELSECNET/H mode or
MELSECNET/10 mode