Setting example
The following is a setting example to perform interlink transmission from the master station on CC-Link IE Field Network to
stations on MELSECNET/H Network. In this example, 128-point data input from the slave station (station No.1) on CC-Link IE
Field Network is transferred.
Slave station
(station No.1)
128
Input
points
CC-Link IE
Field Network
1.
Select "0000: RJ71GF11-T2 (Master Station)" for "Transfer Source Module" and "0020: RJ71LP21-25 (MNET/H Mode
(Normal Station))" for "Transfer Destination Module", and enter the transfer ranges of link devices.
2.
Click the [OK] button.
Master station
Normal station
(station No.0)
(station No.4)
RX
LB
Station No.1 send
range
Station No.2 send
range
RX200
Station No.3 send
·
range
RX27F
LB380
Station No.4 send
·
range
LB3FF
MELSECNET/H
Normal station
(station No.3)
Control station
(station No.1)
Normal station
(station No.2)
2 PARAMETER SETTINGS
2.4 Application Settings
2
77