Appendix 4 List of Link Special Register (SW) Areas
Description
Stores the baton pass status of each station.
Off: Baton pass normal station
On: Baton pass faulty station
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0070
16 15 14 13 12 11 10
SW0071
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0072
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW0073
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
Each number in the table represents a station number.
(Conditions)
• This register is enabled when 'Baton pass error status of own station' (SB0047) is off.
When 'Baton pass error status of own station' (SB0047) is turned on (error), data prior
to error is held.
• Reserved stations and stations exceeding the maximum station number are ignored.
Stores the data link status for each station.
Off: Data link normal station
On: Data link faulty station
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0074
16 15 14 13 12 11 10
SW0075
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0076
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW0077
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
Each number in the table represents a station number.
• When the CPU unit equipped with the MELSECNET/H network module with external
power supply function is turned off, the data link error detection timing may be delayed.
To detect the data link error immediately in this case, create a program by configuring
an interlock with the link relay (LB) in each station's send range.
(Conditions)
• This register is enabled when 'Baton pass error status of own station' (SB0047) is off.
When 'Baton pass error status of own station' (SB0047) is turned on (error), data prior
to error is held.
• Stations exceeding the maximum station number are ignored.
Stores the parameter communication status of each station.
Off: Parameter communication completed or not executed
On: Parameter communication in progress
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0078
16 15 14 13 12 11 10
SW0079
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW007A
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW007B
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
Each number in the table represents a station number.
(Conditions)
• This register is enabled when 'Baton pass error status of own station' (SB0047) is off.
When 'Baton pass error status of own station' (SB0047) is turned on (error), data prior
to error is held.
• This register is enabled only for normally operating stations in 'Baton pass status'
(SW0070 to SW0073).
• Reserved stations and stations exceeding the maximum station number are ignored.
9
8
7
6
5
4
3
2
9
8
7
6
5
4
3
2
9
8
7
6
5
4
3
2
Availability
Control
Normal
station