Technical specifications
13.3 Technical specifications for POM
Power Electronics:
Control version / of heat emitters
Number of outputs / for heating power
Number of heat emitters / per output / maximum
Output voltage / at output / for heating power
Power capacity / per output
Output current / at output / for heating power /
Rated value
Design of short-circuit protection / for heating
power / per output
Melting I2t value
Design of the overvoltage protection
Galvanic isolation / between the outputs
Type of electrical connection / at output / for
heating and fan
Type of connectable conductor cross-section
/ for heating and fan / solid
Type of connectable conductor cross-section
/ for heating and fan / finely stranded / with
core end processing
Type of connectable conductor cross-
sections / at AWG conductors / stranded
Communication:
Design of the interface
Display:
Number of status displays
Display version / as status display by LED
Auxiliary circuit:
Design of the power supply
Active power consumption / maximum
Protective and monitoring functions:
Product function / Temperature monitoring
Type of the temperature monitoring
Diagnostics function
Tripped fuse
Cable break
Heat emitter failure
132
Half-wave control
16
1
230 V
100 W ... 1 449 W
6.3 A
Safety fuse 6.3 A
57 A²·s
Transil Diode
No
Connector, 8-pin
1x (0.2 ... 10 mm²)
1x (0,25 ... 6 mm²)
1x (24 ... 8)
system interface
19
LED green = ready, LED yellow = heating on/off, LED red = error
display, LED red = error for each channel
Power supply via rack
1 W
Yes
NTC thermistor
Voltage diagnostics
Yes
Yes
Yes
Operating Instructions, 11/2015, A5E35066204A/RS-AA/002
Half-wave control and soft start
12
277 V
100 W ... 4 432 W
16 A
Fuse 16 A
68 A²·s
Connector, 6-pin
15