10.2.2

Acyclic input data

The datasets/values described in section "Acyclic output data (Page 95)" can also be read.
Data set 100 "field type 1"
One dataset of the maximum possible length (32 fields) is always returned. A non-assigned
field is entered as channel number 0.
Data set 101 to 132 "field type 2"
One dataset of the maximum possible length (24 channels) is always returned. Unassigned
channels are entered as 0, the same applies to an unassigned field
Data set 150 "Production field value"
One dataset of the maximum possible length (32 fields) is always returned. Setpoint 0 is
entered for unused fields.
Data set 151 "Standby field value"
One dataset of the maximum possible length (32 fields) is always returned. Setpoint 0 is
entered for unused fields.
Dataset 152 "Channels without diagnostic alarm"
The data returned is the data of the channels actually available that belong to the POMs
used.
Data set 160 "Control of internal fans"
The current setting for the fan control is returned.