Panasonic FP2-PP2T Technical Manual page 183

Fp2 positioning unit (interpolation), programmable controller
Table of Contents

Advertisement

Error
Error name
code
Synchronous operation
4031H
method setting error
4042H
Pulser setting error
4043H
Pulser disable error
4044H
Speed rate error
4050H
Startup speed error
JOG positioning
4080H
acceleration/decelerati
on method error
JOG positioning
4081H
acceleration time error
JOG positioning
4082H
deceleration time error
JOG positioning target
4083H
speed error
Home return target
4102H
speed error
Home return
4105H
acceleration time error
Home return
4106H
deceleration time error
Home return setting
4107H
code error
Home return creep
4110H
speed error
Home return returning
4111H
direction error
4112H
Home return limit error
Coordinate origin error
4120H
JOG operation target
4201H
speed error
JOG operation
4203H
acceleration/decelera-
tion type error
JOG operation
4204H
acceleration time error
JOG operation
4205H
deceleration time error
Current value update
4250H
error
Description
The operation setting for the
synchronous operation difference
check function is incorrect.
The pulser input mode is
incorrect.
The pulser operation method is
incorrect.
The pulser operation maximum
speed is incorrect.
The pulse input purpose for the
axis that has been set to enable
the pulser input is not set to
"Pulser".
The setting of the speed rate is
out of the range.
The setting of the startup speed is
out of the range.
The acceleration/deceleration
method of the JOG positioning is
out of the range.
The acceleration time of the JOG
positioning is out of the range.
The deceleration time of the JOG
positioning is out of the range.
The target speed of the JOG
positioning is out of the range.
The target speed of the home
return is out of the range.
The acceleration time of the home
return is out of the range.
The deceleration time of the home
return is out of the range.
The home return setting code is
incorrect.
The creep speed of the home
return is out of the range.
The moving direction of the home
return is out of the range.
The limit switch is disabled.
(It occurs when the home return
method is set to the stop-on-
contact method 1 or 2.)
The coordinate origin is out of the
range.
The target speed of the JOG
operation is out of the range.
The acceleration/deceleration
type of the JOG operaiton is
incorrect.
The acceleraiton time of the JOG
operation is out of the range.
The deceleraiton time of the JOG
operation is out of the range.
The setting value of the current
value update is out of the range.
A: Available N/A: Not available
Object
Clear
Countermeasures
Each axis
A
Check the setting value.
If the error occurred
repeatedly with the correct
setting value, please
Each axis
A
contact us.
Check the the setting of
pulser input purpose.
Each axis
A
Set the input purpose to
"Pulser" when using the
pulser.
Each axis
A
Each axis
A
Each axis
A
Each axis
A
Each axis
A
Each axis
A
Check the setting value.
Each axis
A
If the error occurred
repeatedly with the correct
Each axis
A
setting value, please
contact us.
Each axis
A
Each axis
A
Each axis
A
Each axis
A
Each axis
A
Each axis
A
Each axis
A
Each axis
A
Check the setting value.
If the error occurred
repeatedly with the correct
Each axis
A
setting value, please
contact us.
Each axis
A
Each axis
A
A: Available N/A: Not available