Panasonic FP2-PP2T Technical Manual page 222

Fp2 positioning unit (interpolation), programmable controller
Table of Contents

Advertisement

Offset
Name
address
00EH
Lower limit of
software limit
00FH
010H
-
011H
-
Auxiliary output
012H
mode
Auxiliary output
013H
delay ratio
014H
-
Pulse output
015H
control code
016H
Startup speed
017H
17-32
Descriptions
Sets the lower limit value of the software limit for absolute coordinates.
-
-
Sets the auxiliary output function of the auxiliary output contact and code to be
enalbed or disabled. The time that the auxiliary output contact is on is determined
by the following auxiliary output ON time.
Specify the ratio (%) of output when using the Delay mode for the auxiliary output.
The allowable range is 0 to 100 (%). When specifying 50%, the auxiliary output is
performed if the positioning moving amount exceeds 50%.
Default: 0 (%)
-
Set the pulse output, home, near home and limit signal.
Set the startup speed when starting each operation.
The change in startup speed should be done before starting each operation.
Setting range: 0 to 32,767,000
Any other settings will be errors.
Interpretation is changed by the unit setting.
pulse: 1 to 32,767,000 pps
m: 1 to 32,767,000 m/s
inch: 0.001 to 32,767,000 inch/s
degree: 0.001 to 32,767,000 rev/s
Default: 0
Default
Setting
Unit
value
range