Offset
Name
address
Home return
020H
setting code
Home return
021H
direction
Home return
022H
acceleration
time
Home return
023H
deceleration
time
024H
Home return
target speed
025H
026H
Home return
creep speed
027H
Deviation
028H
counter clear
signal ON time
JOG operation
029H
setting code
17-34
Descriptions
Set the pattern of the home return.
Set the operating direction of the home return.
Set the acceleration/deceleration time when performing the home return.
At the beginning of the home return, accelerates for the specified acceleration
time, decelerates for the specified deceleration time after the proximity input and
changes to the creep speed.
Set the target speed when performing the home return.
When there is no proximity input after starting the home return, accelerates to the
target speed.
Set the speed to search the home position after the proximity input.
Set the value lower than the home return target speed.
Set the ON time of deviation counter clear signal after the completion of home
return.
Default: 1 (ms)
Setting range: 1 to 100 (ms)
When setting a value larger than 100 ms, the time iis 100 ms.
Set the mode of the JOG operation.
Default
Setting
Unit
value
range