17.4.13 System Operation Setting Area

It is used to change the operation of positioning unit.
Offset
Bank
Name
address
Deceleration stop
00H
389H
operation
17-24
Descriptions
Specify the operation when setting the deceleration stop request signal to
"Active" (from OFF to ON).
0: Deceleration stop
When performing the repeat operation, stops after reaching E point
that is targeted for the repeat operation.
1: Pause
- Performs the deceleration stop, and restarts the positioning opration
when turning "Deceleration stop request signal" to OFF from ON.
- Also, performs the same operation as the deceleration stop in all
states except during the positioning operation.
- When performing the repeat operation, stops after reaching E point
that is targeted for the repeat operation, and restarts the positioning
opration when turning "Deceleration stop request signal" to OFF from
ON.
- If the system stop or emergency stop is executed during the pause,
the pause will be cancelled. The operation will not restart even if
turning "Deceleraiton stop request signal" to OFF from ON.
Default: 0