Connecting The Power Cable "Acin" [1] Of Fig. 3.1 (Plug Connector Attached) - Toshiba TH180 Instruction Manual

Industrial robot
Hide thumbs Also See for TH180:
Table of Contents

Advertisement

[7]
External operation input signal cables (OUTPUT)
[8]
Brake signal cable (BRK)
[9]
Distribution I/O cable (EXT-I/O)
In the subsequent paragraphs, we explain how to connect cables  to  inclusive.
For information on how to connect cables  to , refer to the Interface Manual.

3.1.2 Connecting the Power Cable "ACIN" [1] of Fig. 3.1 (Plug Connector Attached)

The power cable is used to supply the main AC power to the controller.
Item
Power supply
Power supply
capacity
Instantaneous power
failure
Grounding
The connector is ACIN (Fig. 3.1-[1]).
Because the cable is not included in the accessories, the customer needs to create it
using the attached plug connector to be connected to ACIN on the controller side.
ACIN plug connector
ACIN cable clamp
Wire
As the cable is not an accessory, use the attached plug connector connected to ACIN
on the controller side to manufacture a cable.
Wires are to be soldered to the connector.
TRANSPORTATION AND INSTALLATION MANUAL
Table 3.1 Power supply specifications
Single phase, AC 200 ~ 240 V, 50/60 Hz±1 Hz
TH250A/TH350A (0.9 kVA)
TH180 (0.5 kVA)
TH350A-T (0.9 kVA)
For 50 Hz, within 40 msec
For 60 Hz, within 32 msec
Dedicated Type D grounding
Type:
JL04V–6A18–10SE–EB
Type: JL04–18CK
2
3.5 mm
~ 5.5 mm
(AWG22 ~ 20)
– 55 –
Specifications
Maker: Japan Aviation
Electronics Industry
Maker: Japan Aviation
Electronics Industry
2
STE 85389