Panasonic Digital Business System - Programming Manual
April 1997
DASSII Incoming Wait Timer
When using a DASSII connection, this timer is the time the DBS will wait after receiving the
Incoming Call Indication and the actual call (opening of the B Channel ) arriving. If this timer
elapses before the call arrives the call will fail and the channel will be dropped. This step has been
moved from FF1 6# 3# 1#.
DASSII Answer Wait Timer
On a DASSII connection, this is the time the DBS will wait for a Call Connect Message, indicating
answer by the called party, following sending of the Initial Service Request Message initiating the
call. After this it will fail the call if no CCM is received. Setting no timer will disable this feature and
the system will wait for CCM until the dialing extension clears. This step has been moved from
FF1 6# 3# 2#.
FF1 6# 6# 3# (1-15)#
1# 0.5 Sec.
2# 1 Sec.
3# 1.5 Sec.
4# 2 Sec.
5# 3 Sec.
6# 4 Sec.
7# 5 Sec.
8# 6 Sec
9# 8 Sec.
10# 10 Sec.
11# 12 Sec.
12# 14 Sec.
13# 16 Sec
14# 20 Sec
15# 25 Sec
FF1 6# 6# 4# (0-15)#
0# No Timer
1# 15 Sec
2# 30 Sec.
3# 45 Sec.
4# 60 Sec.
5# 75 Sec.
6# 90 Sec.
7# 105 Sec.
8# 120 Sec
9# 135 Sec.
10# 150 Sec.
11# 170 Sec.
12# 190 Sec.
13# 210 Sec
14# 230 Sec
15# 250 Sec