Set Local Console - Fujitsu FX-3001SR User Manual

Servis ip-serial 1p converter
Table of Contents

Advertisement

5.1.6.3 set local console

Overview
Sets the local console. If no value is entered and the Enter
key is pressed, the current setting remains.
MAIN MENU → 6. serial → 3. set local console
Menu location
Command
port
Output
--- 6. SERIAL MENU --------
1. set target port
2. set redirect [OFF]
3. set local console
4. set VT100
5. set port number
0. return to MAIN MENU
---------------------------
select > 3
Enter↵
<set local console>
baud rate [300,1200,1800,2400,4800,9600,14400,
19200,28800,38400,57600,115200]
change [115200] to :
<set character size>
size [7:7bit, 8:8bit]
change [8] to :
<set parity bit>
parity [0:none, 1:odd, 2:even]
change [0] to :
<set stop bit>
stop [1:1bit, 2:2bit]
change [1] to :
<set flow>
flow [n:none, h:hardware, x:xon/xoff]
change [n] to :
local port setting completed.
--- 6. SERIAL MENU --------
1. set target port
2. set redirect [OFF]
3. set local console
4. set VT100
5. set port number
0. return to MAIN MENU
---------------------------
select >
Notes
(1) Settings for xon and xoff are from "00" to "ff".
(2) If the entered value does not match one of the choices, an error
message will be displayed for that option.
(3) If Enter is pressed in a blank space, the current setting remains.
Refer to
4.1.17 port Command (page 70)
Enter↵
Enter↵
Enter↵
Enter↵
Enter↵
SERVIS IP-Serial
141
1p Converter
User's Guide
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx-3001srf

Table of Contents