5.1.6.3 set local console
Overview
Sets the local console. If no value is entered and the Enter
key is pressed, the current setting remains.
MAIN MENU → 6. serial → 3. set local console
Menu location
Command
port
Output
--- 6. SERIAL MENU --------
1. set target port
2. set redirect [OFF]
3. set local console
4. set VT100
5. set port number
0. return to MAIN MENU
---------------------------
select > 3
Enter↵
<set local console>
baud rate [300,1200,1800,2400,4800,9600,14400,
19200,28800,38400,57600,115200]
change [115200] to :
<set character size>
size [7:7bit, 8:8bit]
change [8] to :
<set parity bit>
parity [0:none, 1:odd, 2:even]
change [0] to :
<set stop bit>
stop [1:1bit, 2:2bit]
change [1] to :
<set flow>
flow [n:none, h:hardware, x:xon/xoff]
change [n] to :
local port setting completed.
--- 6. SERIAL MENU --------
1. set target port
2. set redirect [OFF]
3. set local console
4. set VT100
5. set port number
0. return to MAIN MENU
---------------------------
select >
Notes
(1) Settings for xon and xoff are from "00" to "ff".
(2) If the entered value does not match one of the choices, an error
message will be displayed for that option.
(3) If Enter is pressed in a blank space, the current setting remains.
Refer to
4.1.17 port Command (page 70)
Enter↵
Enter↵
Enter↵
Enter↵
Enter↵