Section 400-Programming
Notes:
Introduction
An Extension Hunt Group Member cannot also be an Attendant Hunt Group Member.
Each extension can belong to only one Extension Hunt Group. (The most recent assignment is the
priority.)
0
System
To change an Extension Hunt Group Member, clear the current member by pressing FLASH first,
Configuration
then entering the new extension member. Otherwise, the new extension will have the member position,
and the current assignment will move backward one member position. (You cannot override an
extension number, unless you press FLASH to clear it first.)
FF1
Related Programming:
System
FF2
Trunks
Extension HG Delayed (No Answer) Hunt Timer
(all CPCs) - Version 1.0 or higher
FF3
Set the amount of time before an unanswered call ringing an idle member in the
Extensions
Extension Hunt Group, is forwarded to the next member in the group.
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
Notes:
FF7
Applications
Related Programming:
FF8
Maintenance
Appendix A
Appendix B
576-13-400
FF5 1 (01-72) 23 Hold (0-255) Hold
Extension Hunt Group No.
(available range depends on
system size)
(01-12) for a 96-port system
(01-24) for a 192-port system
(01-36) for a 288-port system
(01-48) for a 384-port system
(01-60) for a 460-port system
(01-72) for a 576-port system
DBS 576 (USA) issued 05/20/98
$
, .- %2
Delayed (No Answer) Hunt Timer:
0=stay at idle extension
1-255=no. of seconds
default: 16 seconds
FF5: Groups
Introduction
0
System
Configuration
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
FF7
Applications
FF8
Maintenance
Appendix A
Appendix B
Page 5-15

Advertisement

Table of Contents
loading

Table of Contents