Clear Point; Connectors - HP 8360 User Handbook Manual

8360 series synthesized sweepers
Table of Contents

Advertisement

Clear Point

Function Group
Menu Map 5
Description
Programming Codes
S e e A l s o

CONNECTORS

BNC Connectors
POWER
This softkey lets you change the correction value for the active
frequency point to the "Undefined" state.
SCPI:
NONE, see Fltness Menu
Analyzer:
NONE
"Optimizing Synthesizer Performance" in Chapter 1.
AM/FM OUTPUT
(Option 002 only) Outputs the internally-
generated AM or FM waveform. This output can drive 500 or
greater. The AM output is scaled the same as it is generated, either
chosen. The following table shows the scale versus deviation.
AM INPUT
There are two AM operation modes: linear and log.
When the synthesizer is in linear AM mode, the input accepts a
-1 to +lV signal. With an AM input of OV, the RF output level
(the reference level) is unaffected; at -lV input, the RF is shut off,
and with a +lV input, the RF output is 100% (3 dB) higher that the
reference level. Therefore, there must be 23 dB of margin between
the reference power level and the maximum available at a given
frequency. The on (OV input) to off (-1V input) ratio is a function
of power level and frequency, but is always greater than 20 dB.
The amplitude of the RF output changes linearly as the AM input
changes.
When the synthesizer is in log AM mode, the input accepts a wider
range of input signal. For every -lV input, the RF output level
HP 8360