Function Group
Menu Map 3
Description
Programming Codes
See Also
Manual Sweep
Function Group
Menu Map 7
Description
HP 8360
User's Handbook
MARKER
This softkey lets you set the synthesizer to start sweeping at the
frequency of marker 1 (Ml), and stop sweeping at the frequency of
marker 2 (M2). M2 must have a higher frequency value than Ml. If
Ml, the values of Ml and M2 are permanently interchanged. While
this function is active, the start/stop frequencies of the synthesizer
are changed to the values of Ml and M2. An asterisk next to the key
label indicates this feature is active.
SCPI:
SWEep:MARKer:STATe ONIOFFJ110
Analyzer:
Marker Ml, Start=Ml Stop=MZ
"Marker Operation," in Chapter 1.
"Programming Typical Measurements," in Chapter 1.
SWEEP
This softkey lets you set the synthesizer to the manual sweep mode
of operation. Depending on what parameter is sweeping, you can
use either the rotary knob or the ARROW keys to manually sweep
between the start/stop limits. In manual sweep mode, the synthesizer
does not automatically retrace at the sweep end point (the user must
turn the rotary knob to retrace), and the green SWEEP LED does
not light. The resolution of the rotary knob is 0.1% of the sweep
span in either start/stop or CF/AF mode. The resolution of the
Operating and Programming Reference M-l
M