Operation Problems

Condition
________________________________________________________________________________________________________________________________________________________
Engine continues to run (but
should not) when traction pedal is
depressed with no operator on
seat.
________________________________________________________________________________________________________________________________________________________
Engine kills when traction pedal
is depressed or PTO is engaged.
________________________________________________________________________________________________________________________________________________________
Battery does not charge.
________________________________________________________________________________________________________________________________________________________
Battery continuously charges at
high rate.
®
Groundsmaster
300 Series
Possible Cause
Seat switch plunger depressed
with no operator on seat.
Seat switch faulty or out of
adjustment.
Traction neutral switch faulty or out
of adjustment.
Operator sitting too far forward on
seat (seat switch not depressed).
Seat hinge, support pin or spring
binding, preventing seat switch
from closing.
Seat switch is faulty or out of
adjustment.
Seat switch wiring loose, corroded
or damaged.
Loose, corroded or broken wire(s).
Faulty alternator.
Dead battery.
Regulator / rectifier faulty.
Page 6 - 9
Correction
Check for seat support spring
that is broken, missing or stuck in
down position.
Check for binding seat pivot
hinge.
Check for waterlogged seat.
Test seat switch. Adjust or
replace if faulty.
Test switch, Adjust or replace if
faulty. Check for correct terminal
connections.
Instruct operator.
Repair seat pivot and support.
Test seat switch. Adjust or
replace if faulty.
Repair wiring.
Repair wiring.
Test alternator and replace if
faulty.
Charge battery. Replace battery if
it will not hold a charge.
Replace regulator / rectifier.