Toro Groundsmaster 300 Series Service Manual page 267

Hide thumbs Also See for Groundsmaster 300 Series:
Table of Contents

Advertisement

34. Put the three 1/2 in. (13 mm) springs into the spring
pockets of the isolation manifold (Fig. 97).
NOTE: Two different length springs are used in the unit.
Be sure to use the 1/2 in. (13 mm) length springs during
this part of the assembly.
35. Apply clean grease to a seal ring and put it in the
valve ring recess that will face down when installed.
Install the valve ring over the bolts and alignment pins
with the seal ring facing the isolation manifold (Fig. 98).
IMPORTANT: Be sure the seal ring is seated cor­
rectly after the valve ring is assembled.
36. Put the hex drive assembly, pin side up, through the
hole in the isolation manifold (Fig. 99). the slot in the hex
drive must be engaged with the SMALL tang of the drive
link. Turn the input shaft to assist the engagement.
NOTE: If the hex drive does not readily assemble on the
drive link, the drive link was assembled incorrectly (See
step 22 of this procedure.)
®
Groundsmaster
300 Series
Page 8 - 47
Figure 97
Figure 98
Figure 99
Repairs

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents