Toro Groundsmaster 300 Series Service Manual page 179

Hide thumbs Also See for Groundsmaster 300 Series:
Table of Contents

Advertisement

PTO Switch Replacement (Fig. 26, 27)
Lever Type Switch (S/N Below 30001) (Fig. 26)
1. Disengage latches and remove instrument cover.
2. Disconnect negative battery cable from battery and
separate wire harness connectors.
3. Move PTO lever to the ON position and remove
capscrew and locknut holding switch against mounting
bracket.
4. Install new switch with capscrew and locknut. Move
PTO lever to OFF position. When lever is in its normal,
released position, the switch arm must bend about 1/2
inch (13 mm). If switch arm does not bend 1/2 inch
(13 mm), bend the mounting bracket to get the correct
adjustment.
5. Connect a continuity tester or ohm meter to switch
connector. With PTO lever in forward (ON) position, the
switch circuit should have no continuity. If there is con-
tinuity, check switch installation. If there is no continuity,
go to next step.
6. Move PTO lever to OFF position. When PTO lever is
in its normal, released position, the PTO switch should
have continuity. If there is no continuity, check switch
installation. If there is continuity, go to next step.
7. Liberally coat inside of wiring connectors with skin-
over grease. Push wire harness connectors together.
Connect negative battery cable to battery.
8. Install instrument cover and lock the latches.
®
Groundsmaster
300 Series
1. Connectors
2. PTO lever
3. Capscrew & locknut
4. Switch
Page 6 - 33
Figure 26
(S/N Below 30001)
5. Mounting bracket
6. Switch arm
7. 1/2 inch (13 mm)