Siemens SINAMICS S120 Getting Started page 43

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

3.2
Configuring the drive unit
The following components are required to assemble the drive unit used in this example:
S Active Line Module
S Motor Module
S Synchronous motor (e.g. 1FK6) with sensor for servo control variant
S Induction motor (e.g. 1PH7) with sensor for vector control variant
To assemble the drive unit components, proceed as follows:
1. In the project navigator, open the SINAMICS_CU320 directory and double–click
the element Configure drive unit (see Fig. 3-14).
As you can see in Fig. 3-15, the STARTER opens a Wizard for configuring the
drive unit components.
Fig. 3-15
2. An option board is not used in this example.
Confirm the default setting No option board by choosing Continue > to carry
out the next configuration step.
 Siemens AG 2006 All rights reserved
SINAMICS S120 Getting Started with the STARTER Commissioning Tool – 03/2006 Edition
Configuration – SINAMICS CU320 option board
Creating the Drive Project OFFLINE
3-43