Siemens SINAMICS S120 Getting Started page 62

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Using the STARTER Control Panel (Motor Rotates)
Table 4-1
Signal
(control panel)
ON/OFF1
ON/OFF2
ON/OFF3
Pulse enable
Ramp–function
generator
enable
Start/stop
ramp–
function
generator
Enable
setpoint
Fig. 4-9
5. As shown in Fig. 4-9, click the Enables field to set the commands for enabling
the control words in the drive system.
Fig. 4-10
6. Click Infeed control priority. The infeed (Active Line Module) is powered–up.
4-62
Control word sequence control
PROFIdrive
Bit No. in STW
sequence control
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Click in the field
Enables.
Enables
Click
Infeed control priority.
Infeed control priority
SINAMICS S120 Getting Started with the STARTER Commissioning Tool – 03/2006 Edition
Meaning
0 = OFF (OFF1), stop via ramp–function generator,
followed by pulse block
1 = ON, operating condition
0 = Coast down (OFF2), pulse block, motor coasts
to standstill
1 = Do not coast down, operating condition
0 = Emergency stop (OFF3)
1 = No emergency stop, operating condition
0 = Disable operation, pulse block
1 = Enable operation, enable pulses
0 = Set ramp–function generator to 0
1 = Enable ramp–function generator
0 = Freeze ramp–function generator, retain
current output value
1 = Restart ramp–function generator, follows the
input value
1 = Enable setpoint
0 = Block setpoint and set to 0
 Siemens AG 2006 All rights reserved