Hitachi COMPUTE BLADE 500 SERIES Management Module Setup Manual page 246

Hide thumbs Also See for COMPUTE BLADE 500 SERIES:
Table of Contents

Advertisement

Power consumption specification for server blades:
Rating power consumption (Maximum): 400 W
Maximum power consumption when capping to the minimum value: 150
W
Number of server blades installed: 4
Disabled APC for server blade 0, 1, and 2
When the total power consumption of the chassis exceeds the APC
maximum, power consumption of sever blade 3 will be limited. Disabling
the power capping is not available because of subtracting 400 W x 3 for
rating power consumption of server blade 0, 1, and 2 with power capping
disabled from 1300 W and getting 100 W, which is less than the
maximum power consumption when capping to the minimum value: 150
W.
1
Operation status 1 (Operating within the maximum power consumption)
.
2
Operation status 2 (Exceeding the maximum power consumption)
.
2-222
Hitachi Compute Blade 500 Series Management Module Setup Guide
Functional detail

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents