1
Copy CBTP ISO image in the flash memory embedded in the server
.
chassis.
Connect to the management module via FTP, and make sure to transfer
CBTP ISO image to the directory, iusb/iso/diag.
Tip:
Make sure to add ".iso" as an extension to the file for transfer. The
extension is not case-sensitive.
Up to 10 ISO images can be transferred. Even if ISO images more
than 10 are transferred, only 10 images from the top in ASCII code
order can be recognized by the management module.
Up to 118 characters are available for an ISO image file name. If an
ISO image with 119 characters or more is transferred, it cannot be
recognized by the management module.
The following is an example of Windows command prompt, which uses IP
address (192.168.0.1) and account (User: Administrator, Password:
password) that are set by default. The ISO image file name to transfer is
CBTP_v3.1.13_multi_forCS_1212201007.iso in the example below.