Hitachi COMPUTE BLADE 500 SERIES Management Module Setup Manual page 358

Hide thumbs Also See for COMPUTE BLADE 500 SERIES:
Table of Contents

Advertisement

FF44
[Meaning] An failure was detected on the active port of the management NIC.
<X> indicates the location, and <Y> indicates the event that occurred.
[Action] Do the following:
(1) Confirm that the cable and switch from the port on the management NIC at the
indicated location to the management module are correctly set and running. After
confirmation, perform an immediate diagnosis.
(2) If a non-redundant management NIC is used, or this event occurred at both ports of
the management NIC, check the management module for failure. If a failure is found,
perform troubleshooting for the management module.
FF45
[Meaning] An failure was detected on the standby port of the management NIC.
<X> indicates the location, and <Y> indicates the event that occurred.
[Action] Do the following:
(1) Confirm that the cable and switch from the port on the management NIC at the
indicated location to the management module are correctly set and running. After
confirmation, perform an immediate diagnosis.
(2) If a non-redundant management NIC is used, or this event occurred at both ports of
the management NIC, check the management module for failure. If a failure is found,
perform troubleshooting for the management module.
FF46
[Meaning] An failure occurred on the management NIC.
<X> indicates the location, and <Y> indicates the event that occurred.
[Action] If the event that occurred is "Switched between active and standby", the
redundancy of the management path and port might be lost. If there is an failure alert
message about the management NIC, take measures for it.
If the event that occurred is other than "Switched between active and standby", no
action is required.
FF47
[Meaning] The LPAR manager functions are unavailable owing to port number
duplication.
<X> indicates the location, and <Y> indicates the event that occurred.
[Action] Check the port number settings, and reassign the port numbers.
FF48
A-14
Hitachi Compute Blade 500 Series Management Module Setup Guide
ID
Level
FAIL
Warning
Information
Warning
Information
HCSM alert log message
Description
An failure event occurred on the
management NIC port.(Location:<X>,
Event:<Y>)
A warning event occurred on the
management NIC port.(Location:<X>,
Event:<Y>)
An event occurred on the management
NIC port.(Location:<X>, Event:<Y>)
The function is unavailable owing to port
number duplication.(Location:<X>,
Function:<Y>)
The port number(s) for the function was
recovered from duplication.
(Location:<X>, Function:<Y>)
Message