NEC SL1100 Networking Manual page 257

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

NEC SL1100
Program
Number
10-19-01
10-20-01
90-10-01
90-10-02
Networking Manual
Program Name/Description
VoIPDB DSP Resource
Selection
This program is used to assign
the 16 or 32 resources of the
VoIPDB.
NEC recommends leaving the
default settings as system
default.
External Equipment LAN setup
Device type 4 (networking
system) must be assigned to
the same port number in ALL
SL Net systems.
System Alarm Setup
Two Alarms were added for SL
Net and they are:
Alarm 15 – Networking keep
alive error
Alarm 59 – Networking port limit
exceeded
Report
This program is used to assign if
the alarm is displayed on a key
telephone if the alarm
information is reported to the
pre-defined destination.
Assigned Data
.
0 = Commonly used for IP extensions,
trunks, and networking
1 = Use for IP extensions
2 = Use for SIP trunks
3 = Use for networking (SL Net)
5 = Blocked
6 = Common without unicast paging
7 = Multicast paging
8 = Unicast paging
(defaults: resource1 = Use for IP extensions,
resource 2 ~ 32 = Common)
1 = CTI Server (default = 8181)
2 = ACD MIS (default = 4000)
4 = Networking System (default = 30000)
5 = SMDR Output (default = 0)
6 = DIM Output (default = 0)
9 = 1st Party CTI (default = 8282)
11 = O&M Server (default = 8010)
12 = Traffic Report Output (default = 0)
13 = Room Data Output for Hotel Service
(default = 0)
14 = IP-DECT Directory Access (default = 0)
Available values are: 0 ~ 65535
0 = No Setting
1 = Major Alarm
2 = Minor Alarm
(Refer to the SL1100 programming manual
for the default values.)
0 = No (alarm disabled)
1 = Yes (alarm enabled)
(Refer to the SL1100 programming manual
for the default values.)