CHAPTER 6 TROUBLESHOOTING
III. TROUBLESHOOTING
A.

Finisher Unit

1.
Fault in communication with host machine
Cause
Finisher controller PCB,
Host machine DC
controller PCB
Wiring
Finisher controller PCB,
Host machine DC
controller PCB
2.
Fault in communication with saddle stitcher unit
Cause
Finisher controller PCB,
Saddle stitcher controller
PCB
Wiring
Power supply
Saddle stitcher controller
PCB
6-22
Step
Checks
1
Turn the host machine OFF
then ON. Is the problem
corrected?
2
Is the wiring between the
finisher controller PCB and
the host machine controller
PCB normal?
3
Replace the finisher controller
PCB and the host machine DC
controller PCB. Is the
problem corrected?
Step
Checks
1
Turn the host machine OFF
then ON. Is the problem
corrected?
2
Is the wiring between the
finisher controller PCB and
the saddle stitcher controller
PCB normal?
3
Measure the voltage between
J19-1 (+) and J19-2 (−) on the
finisher controller PCB. Is it
24 VDC?
Yes/No
Action
Yes
End.
No
Correct it.
Yes
End.
No
Mulfunction of the
host machine.
Yes/No
Action
Yes
End.
No
Correct it.
No
Replace the finisher
controller PCB.
Yes
Replace the saddle
stitcher controller
PCB.

Hide quick links: