Table 3-21     Problems resolved in versions prior to XCP 2050 (continue d)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
121113-025
RTIF2-
x
x
x
121113-027
RTIF2-
x
x
x
121113-031
RTIF2-
x
x
x
121129-001
Description
When a CPU failure occurs, an error
message showing degradation or offline
on Oracle Solaris may not be output to
Syslog.
If you update the firmware and then
upload XCP with XSCF Web without
restarting XSCF, uploading of XCP will
fail and the XSCF Web session will time
out.
After creating an I/O domain to which
the PCI card is assigned with Oracle VM
Server for SPARC, turn on the power of
the I/O domain. If you then stop it in ok
prompt, the configuration information of
the PCI card may not be displayed with
the showhardconf(8) command of XSCF.
During operation of the XSCF firmware,
a "system backup memory access error",
which is an error in the PSU backplane
(PSUBP), may be erroneously detected
and registered in the error log. If this
erroneous detection occurs during the
start process of the physical partition
(PPAR), the start of the PPAR may fail.
Also, if it occurs during the collection of
log information, the log information
collection fails. In addition, a failure
mark may be displayed on the PSUBP
when the error is detected. If the failure
mark is displayed on the PSUBP, the
resources necessary for starting the PPAR
are insufficient. Therefore, when start of
the PPAR is requested, a log indicating
that the start of the PPAR failed is
registered in the power log. You can
display the power log with the showlogs
power command.
Workaround
Use the showlogs(8) command to check a
failure state on XSCF.
If you update the firmware and then
continue to upload XCP with XSCF Web,
restart XSCF.
Start Oracle Solaris of the logical domain
to which the PCI card is assigned with
Oracle VM Server for SPARC.
If you find a log described in "Description,"
execute the showstatus(8) or showhardconf
(8) command to check whether the failure
mark is displayed on the PSUBP.
- When the failure mark is not displayed
on the PSUBP:
No problem has occurred in the
hardware. So, ignore the error log and
continue the operation.
- When the failure mark is displayed on
the PSUBP:
Clear the failure mark by using the
following procedure.
1. Switch the mode switch on the
operation panel to the Service mode
position.
2. Turn the power to the target SPARC
M10 system chassis off and then on
again, and then restart the XSCF. For
the M10-4S, turn the power to every
SPARC M10-4S chassis off and then
on again.
3. After the XSCF has been restarted,
return the mode switch on the
operation panel to its original position.
If the same error recurs even after
restarting the XSCF, there is a possibility
that the error has not been erroneously
detected but that a PSUBP hardware
failure has occurred. Ask your Fujitsu
field engineer (service provider) to
replace the PSUBP.