Fujitsu M10 Product Notes page 64

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-5     Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
131213-019
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
50
Description
While XSCF is starting after being
powered on, watchdog timeout may
occur and XSCF is reset. After this reset is
completed, the configuration information
of the components mounted on the
system cannot be checked by the
showhardconf(8) command.
Moreover, error logs regarding the
following configurations may be
registered.
Msg:Indispensable parts are not installed
(PSU).
Msg:Indispensable parts are not installed
(FAN).
Msg:Indispensable parts are not installed
(OPNL).
Msg:PSU shortage
Msg:FAN shortage
Workaround
There is no effective workaround.
[How to restore]
Re-execute power off and on.