Fujitsu M10 Product Notes page 62

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-5     Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
131213-011
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
48
Description
When a SPARC M10-4S or a crossbar box
is added using the addfru(8) command,
the following message is output and the
addition may fail.
[Warning:036]
Failed to find BB#x.
The BB-ID setting and/or the cable
connections of the BB#x will be wrong.
Please confirm the BB-ID setting and the
cable connections.
Do you want to try to add BB#x again?
[a:add|c:cancel] :
Workaround
When the following maintenance menu
is output after executing the addfru(8)
command, input power on the SPARC
M10-4S or the crossbar box to be added
and execute the next operation (step 2)
after 20 minutes.
Please execute the following steps:
1) After the added device is connected
with the system, please turn on the
breaker of the BB#x.
2) Please select[f:finish] :
[How to restore]
Input "a" in response to the "[a:add|c:
cancel] :" message and re-execute the
addfru(8) command.