Fujitsu M10 Product Notes page 73

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-5     Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
Description
The following settings are excessively
restored on the same or other chassis.
- Information on the time difference
between XSCF and the hypervisor of
each physical partition (PPAR)
The following settings are excessively
restored on other chassis.
- Setting values for the LDAP client, set
with the setldap(8) command
- Setting values for the LDAP over SSL
client, set with the setldapssl(8)
command
- Configuration setting values for the
Active Directory, set with the setad(8)
command
- Setting values for the SNMP agent, set
with the setsnmp(8)/setsnmpusm(8)/
setsnmpvacm(8) command
- Setting values for the SMTP service, set
with the setsmtp(8) command
- Setting values for the e-mail notification
function, set with the setemailreport(8)
command
Furthermore, since the PPAR DR feature
setting values cannot be saved/restored,
powering on the PPAR after executing
the following procedure switches the
logical domain configuration information
to the factory-default state.
1. Execute the setpparmode -p ppar_id -m
ppar_dr command to enable/disable the
PPAR DR feature.
2. Execute the dumpconfig(8) command
to save XSCF setting information.
3. Initialize the chassis to factory defaults
by executing the initbb(8) or the
restoredefaults(8) command.
4. Restore the XSCF configuration
information of the chassis in procedure
3 with executing the restoreconfig(8)
command.
5. Power on the PPAR by executing the
poweron(8) command.
Workaround
changes
[Example] Saving management file to ftp
server when registering one power
supply interlocking group
XSCF> getremotepwrmgmt -G 1
ftp://server[:port]/path/file
Power supply interlocking function
enable/disable setting
[Example] Enabled
XSCF> showremotepwrmgmt
[Remote Power Management Group#01
Information]
Remote Power Management Status
:[Enable]
--- Omitted ---
- Time difference between XSCF and
the hypervisor of each PPAR
[Example] If there is a time difference
between XSCF and the
hypervisor of each PPAR
XSCF> showdateoffset -a
PPAR-ID Domain Date Offset
00
12 sec
01
12 sec
--- Omitted ---
15
12 sec
2. Execute the dumpconfig(8) command
to save the XSCF setting information.
3. If the XSCF setting information is to be
restored on another chassis, execute the
restoreconfig(8) command on that
chassis to confirm the following
settings before restoring the XSCF
setting information.
- LDAP client setting
[Example] To display all LDAP setting
information except the CA certificate and
password
XSCF> showldap
Bind Name:
Base Distinguished Name: Not set
LDAP Search Timeout:
Bind Password:
LDAP Servers:
CERTS: None
Chapter 3 Information on Software
Not set
60
Not set
Not set
59