Notes On Timezones; Notes On Power Supply Interlock Function (Rcil) - Fujitsu M10 Product Notes

Hide thumbs Also See for M10:
Table of Contents

Advertisement

function of the control domain.
XSCF>   setpparparam -p xx   -s bootscript "setenv auto-boot? false"
XSCF>
13. Similarly, execute the ldm add-spconfig command for the guest domain after
adjusting the time of Oracle Solaris.

Notes on Timezones

The time zones (regions/place names) supported by the XSCF can be changed to
support the latest time zone information.
For any previously set time zone that the system cannot use anymore, the XSCF
switches from this unusable time zone to Coordinated Universal Time (UTC) and
operates in UTC.
When the set time zone operates in UTC, execute the settimezone -c settz -a
command, and check the settable time zones. If the time zone list does not have a set
time zone, set a time zone again.

Notes on power supply interlock function (RCIL)

Do not register the same node with multiple power supply interlocking groups. If
power supply interlocking is performed by registering a single node with multiple
power supply interlocking groups, the operation may not be as intended.
With the setremotepwrmgmt(8) command, you cannot confirm whether a single
node is registered with multiple power supply interlocking groups. When creating
or modifying a power supply interlocking group management information file,
take care not to cause overlaps.
Do not register an I/O node with multiple power control groups. If the same I/O
node is set with multiple power supply interlocking groups, and both of the
conditions below are met, the I/O node is turned on and off alternately.
- setremotepwrmgmt -c enable is executed, and the power supply interlocking
function is enabled.
- There is a power control group in which one or more host nodes are on, and
there is a power control group in which all the host nodes are off.
If you accidentally register an I/O node with multiple power control groups, use
setremotepwrmgmt -c disable to disable power supply interlocking first and then
use clearremotepwrmgmt to delete the power control group setting. After
deletion, create a power supply interlocking group management information file
so that the I/O node is not registered with multiple groups, and then use
setremotepwrmgmt -c config to register it again.
If XCP 2080 or earlier is used together with a single SPARC M10 system that is
connected to an external I/O device, do not use the power supply interlocking
function. The external I/O device may be erroneously powered off when the XSCF
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015