Table 3-5     Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
140410-005
RTIF2-
x
140410-008
RTIF2-
x
140410-009
RTIF2-
x
140507-003
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
66
Description
If a hardware error is detected
immediately after powering off or
restarting the physical partition (PPAR),
the PPAR power off or restart process
may be stopped, and may not be
completed.
To check whether this phenomenon has
occurred, power off or restart the PPAR
and then execute the showpparprogress
(8) command. If the PPAR remains in the
power on state and the power off process
has not completed after at least one
minute has passed, this phenomenon has
occurred.
[Example of unsuccessful power off]
XSCF> showpparprogress -p 0
This PPAR is powered on.
Normally, when the PPAR power off
completes, the power off sequence and
PPAR state are as follows.
[Example of successful power off]
XSCF> showpparprogress -p 0
PPAR Power Off
CPU Stop
PSU Off
The sequence of power control is
completed.
Even if the XSCF DUAL control cable is
reconnected after the system input power
has been turned on with this cable
disconnected, data synchronization
between the master chassis and standby
chassis cannot be secured. Continuous
system operation is possible. However,
after switching the master and standby
XSCFs, normal system operation is not
guaranteed. This is because information
in the old master XSCF is not reflected in
the new XSCF.
If the input power to the standby or slave
chassis is turned off, a "Board control
error (MBC link error)" error log may be
registered.
After adding or removing a system board
with the dynamic reconfiguration of
physical partitions (PPAR), if the PPAR is
powered off, the output of the
Workaround
There is no effective workaround.
[How to restore]
If the PPAR power supply remains in the
power-on state 30 minutes after
executing the showpparprogress(8)
command, turn off the input power to all
chassis and then turn it on again
(AC-OFF/ON).
PPAR#0 [1/3]
PPAR#0 [2/3]
PPAR#0 [3/3]
Before turning on the input power,
confirm that the XSCF DUAL control
cable is correctly inserted.
[How to restore]
Execute the rebootxscf -a command to
reset all XSCFs.
There is no effective workaround.
Ignore this error log.
There is no effective workaround.
[How to Restore]
After the "PPAR-ID x: Reset" message is
output to the event log, re-execute the