Confirmation method of RTIF2-140902-002
The phenomenon of RTIF2-140902-002 can be checked in the following ways.
1.
The phenomenon of RTIF2-140902-002 can be checked in the following ways.
- FRU displays "LINK" or "LINKBD"
- Msg displays "TWI access error"
- The first byte in the fourth line of the Diagnostic Code is "07"
[Example of incorrect registration]
XSCF> showlogs error -v
Date: Dec 20 10:50:05 JST 2013
Code: 80000480-001f010021ff00cc01-11000057d000000000000000
Status: Alarm Occurred: Dec 20 10:49:59.136 JST 2013
FRU: /MBU/PCI#1/LINK,/MBU/PCI#1/LINK/MGCBL,/MBU/PCI#1/PCIBOX#3001/LINKBD,*
Msg: TWI access error
Diagnostic Code:
00010000 00000000 0000
00010000 00000000 0000
00013330 30310000 0000
07100000 00000000 00000000 00000000
^^
00000000 00000000 0000
2.
When the showlogs event command or showlogs error command are executed
on the same PCI expansion unit within 10 minutes, multiple logs shown below
are registered.
- 12 or more event logs related to the PCIe card are registered upon executing
XSCF> showlogs event
Dec 20 10:49:59 JST 2013 Attach operation (/BB#0/PCI#1/
PCIBOX#3001/PCI#1) Dec 20 10:49:59 JST 2013 Detach
operation (/BB#0/PCI#1/PCIBOX#3001/PCI#1)
--- Omitted ---
- Six or more logs are registered by the PCI expansion unit firmware (the first
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
194
the showlogs event command. The number of event logs is calculated as
follows depending on the event type.
- Event of PCIe card insertion: 2
- Event other than PCIe card insertion: 1
For example, if a PCIe card is repeatedly inserted and removed four times,
eight message lines are displayed. However, the number of registered event
logs is 12, which is calculated by multiplying three events by four. This
applies to this case.
[Example of PCIe card insertion/removal]
byte in the third field of Code is 11) upon executing the showlogs error
command.