Fujitsu M10 Product Notes page 164

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-21     Problems resolved in versions prior to XCP 2050 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
121219-012
RTIF2-
x
121219-013
RTIF2-
x
121219-014
RTIF2-
x
121219-015
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
150
Description
When a SPARC M10-4S chassis is
replaced using the replacefru(8)
command, replacement of the SPARC
M10-4S chassis may fail with "internal
error" displayed.
When a SPARC M10-4S chassis finds an
error indicating that the XSCF cannot be
started, not only an error log for the
SPARC M10-4S chassis where the error
occurred but also an error log regarding
a cable connection error in a chassis that
does not exist may be registered.
When cold replacement is performed
(replacement performed while the input
power is off) due to an error with BB#00,
the setting information for the XSCF is
deleted.
When a SPARC M10-4S chassis is
removed with the initbb(8) command,
the information on the removed chassis
remains without being completely deleted.
Workaround
Use the following procedure to replace a
SPARC M10-4S chassis by using the
replacefru(8) command.
1. Enter "r" to replace the chassis in
response to the message "Do you want
to continue?[r:replace|c:cancel]" which
is displayed after the replacefru(8)
command is executed.
2. Replace the SPARC M10-4S chassis
and wait for about 15 minutes after the
input power of the chassis is turned on.
3. Execute the showlogs event command
to display an event log.
4. Continue the replacement using either
of the following methods.
- If the event log displays "XSCF update
is started"
Wait until the "XCP update has been
completed" log is registered. When
"XCP update has been completed" is
displayed, enter "f" in response to
"Please select[f:finish]" and then
continue the replacement by following
the instructions displayed on the screen.
- If the event log does not display
"XSCF update is started"
Enter "f" in response to "Please
select[f:finish]" and then continue the
replacement according to the
instructions on the screen.
Ignore the error log regarding a cable
connection error registered for a SPARC
M10-4S chassis that does not exist.
To replace a SPARC M10-4S chassis due
to an error in BB#00, use the replacefru(8)
command.
To remove a SPARC M10-4S chassis,
perform the cold removal (the chassis is
removed by turning off the input power).

Advertisement