Table 7- 8
Note
Safety markings for hazardous areas
Since there is not enough space on the MDS D124 for the safety mark, this is supplied as a
label with the device.
This must be affixed immediately next to the MDS D124 so that the label clearly relates to
the device.
Danger due to electrostatic discharge
NOTICE
Installation and operating conditions for hazardous areas:
• The device may not be used in areas influenced by processes that generate high
• The device must be installed so that it is mechanically protected.
• For applications requiring devices of category 1, the device must be mounted on a
• It must only be cleaned with a damp cloth.
• The device is suitable for use in atmospheres containing dust, however not for full
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Ambient temperature
Ambient temperature range
-25 ... +150 ℃
-25 ... +100 ℃
-25 ... +65 ℃
-25 ... +50 ℃
WARNING
electrostatic charges.
grounded, conductive base.
immersion in dust.
Temperature class
T3
T4
T5
T6
Transponder
7.3 MDS D124
Max. surface temperature
T180
T130
T95
T80
167