Pin Assignment Rf210R With Rs422 Interface; Display Elements Of The Rf210R Reader - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

5.1.3

Pin assignment RF210R with RS422 interface

Pin
5.1.4

Display elements of the RF210R reader

Color
green
yellow
flashing red
1)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Pin
Device end
8-pin M12
1
2
3
4
5
6
7
8
Meaning
flashing
Operating voltage present, reader not initialized or antenna switched off
permanently
Operating voltage present, reader initialized and antenna switched on
lit
Transponder present
1)
Error has occurred, the type of flashing corresponds to the error code in the
table in the section "Error codes". The optical error display is only reset if the
corresponding reset parameter ("option_1 = 2") is set (see Product
information "SIMATIC RF200 command set"
(http://support.automation.siemens.com/WW/view/en/44864850)).
Only in the "with presence" mode.
Assignment
+ 24 V
- Transmit
0 V
+ Transmit
+ Receive
- Receive
Unassigned
Ground (shield)
Readers
5.1 SIMATIC RF210R
77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf200

Table of Contents