Table 4- 22
Transponder
MDS D124
MDS D160
MDS D324
MDS D421
MDS D422
MDS D423
MDS D424
MDS D425
MDS D428
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Reduction of field data by metal: Transponder and RF250R with ANT 18
without metal
1)
on metal, distance 25 mm
flush-mounted in metal;
distance all round 25 mm
without metal
1)
on metal, distance 25 mm
flush-mounted in metal;
distance all round 25 mm
without metal
1)
on metal, distance 25 mm
flush-mounted in metal;
distance all round 25 mm
without metal
flush-mounted in metal
without metal
flush-mounted in metal
without metal
screwed onto metal
flush-mounted in metal;
without surround
without metal
1)
on metal, distance 25 mm
flush-mounted in metal;
distance all round 25 mm
without metal
screwed onto metal
flush-mounted in metal;
distance all round 25 mm
without metal
screwed onto metal
flush-mounted in metal;
distance all round 25 mm
RF200 system planning
4.3 Installation guidelines
RF250R with ANT 18
antenna without
antenna flush-
metal
mounted in metal
(all round 10 mm)
100
100
95
100
100
90
100
100
95
100
65
100
90
100
160*
95
100
95
95
100
100
100
100
100
100
80
80
70
90
90
80
80
80
75
85
50
100
90
85
120*
75
75
75
75
90
90
90
85
85
85
57