7.5.4
Technical specifications
Table 7- 12
Technical specifications for MDS D127
Memory size
Memory configuration
Serial number
•
Configuration memory
•
Application memory
•
Storage technology
Memory organization
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles (at +40 °C)
minimum
•
Typical
•
Read/write distance (S
)
g
Multitag capability
Power supply
Degree of protection according to EN 60529
Degree of protection according to DIN 40050 Part 9
Shock according to EN 60721-3-7, Class 7M3
Total shock response spectrum, Type II
Vibration-resistant to EN 60721-3-7, Class 7M3
Torsion and bending load
Housing
Dimensions (D x H)
•
Color
•
Material
•
Securing
Ambient temperature
Weight
2 hours, 2 m, +20 °C
1)
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
2)
The values for shock and vibration are maximum values and must not be applied continuously.
3)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
During operation
During transportation and
storage
128 bytes
8 bytes (fixed code)
•
8 bytes
•
112 bytes
•
EEPROM
Refer to the RF200 or RF300 system manual, section
"Memory configuration of the ISO tags"
10 years
≥ 2 x 10
hours
6
unlimited
100 000
•
1 000 000
•
See section "Field data (Page 35)"
Yes
inductive power transmission (without battery)
IP68
1)
IPx9K
2)
100 g
3)
20 g 3)
not permitted
M6 x 5 mm (±0.2 mm)
•
Black
•
Plastic PA6
•
Screw-in, cemented
-25 ... +100 ℃
-40 ... +125 ℃
Approx. 1 g
Transponder
7.5 MDS D127
173