Technical Data - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

6.7.6

Technical data

Technical specifications
Max. write/read distance
ANT to MDS (S
)
g
Dimensions (L x W x H)
Color
Material
Plug connection
Max. power
Antenna cable length
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
Vibration according to EN 60721-3-7 Class
7M2
Attachment of the antenna
Ambient temperature
During operation
During transportation and storage
MTBF
Degree of protection according to EN 60529
Weight, approx.
Approvals
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
480 mm
1150 x 365 x 115 mm
(with cover)
gray/black
Aluminum/plastic
1-pin TNC connector
10 W
(FCC/IC: 2.5 W)
3.3 m
30 g
1 g (9 to 200 Hz) / 1.5 g (200 to 500 Hz)
4 x M6 screws
-20 ℃ ... +55 ℃
-25 ℃ ... +70 ℃
3 x 10
hours
5
IP65 (UL: for indoor use only)
10 kg
(with cover)
CE
FCC, IC (as of 04/2013)
Antennas
6.7 ANT D10
153

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf200

Table of Contents