Application Example Of Mds D425; Technical Specifications - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

7.18.3

Application example of MDS D425

Figure 7-48
7.18.4

Technical specifications

Table 7- 36
Technical data of MDS D425
Memory size
Memory configuration
Serial number
Configuration memory
Application memory
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF
Data rate
read/write
Bulk detection/multitag capability
Read cycles
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Application example
2048 bytes
8 bytes (fixed code)
40 bytes
2000 bytes
FRAM
2048 bytes gross
2000 bytes net
when using the OPT area, 16 bytes of this must be
subtracted in 8 byte blocks
ISO 15693
10 years
≥ 2 ° 10
h
6
approx. 2 ms/byte
Yes
unlimited
Transponder
7.18 MDS D425
225