Accessories
8.3 Wide-range power supply unit for SIMATIC RF systems
8.3.2

Scope of supply

● Wide-range power supply unit for SIMATIC RF systems
● 2 m mains cable (country-specific)
● Protective cover for flange outlet
● Operating Instructions
8.3.3

Ordering data

Table 8- 6
Wide-range power supply unit for SIMATIC RF systems (100 -
240 VAC / 24 VDC / 3 A) with 2 m connecting cable with country-
specific plug
24 V-connecting cable, length 5 m
8.3.4

Safety Information

Danger to life
It is not permitted to open the device or to modify the device.
The following must also be taken into account:
• Failure to observe this requirement shall constitute a revocation of the CE approval, UL
• For installation of the power supply, compliance with the DIN/VDE requirements or the
• The field of application of the power supply unit is limited to "Information technology
• When the equipment is installed, it must be ensured that the mains socket outlet is
• The housing can reach a temperature of +25 °C during operation without any adverse
250
Ordering data for wide-range power supply unit
WARNING
certification for the US and Canada as well as the manufacturer's warranty.
country-specific regulations is essential.
equipment" within the scope of validity of the EN 60950/VDE 0805 standard.
freely accessible.
consequences. It must, however, be ensured that the power supply is covered in the
case of a housing temperature of more than +25°C to protect persons from contact with
the hot housing. Adequate ventilation of the power supply must be maintained under
these conditions.
Order number
EU: 6GT2898-0AA00
UK: 6GT2898-0AA10
US: 6GT2898-0AA20
6GT2491-1HH50
System Manual, 09/2013, J31069-D0227-U001-A8-7618