ISO transponder
Description
MDS D424
MDS D425
MDS D426
MDS D428
MDS D460
Table A- 7
Communication modules/interface modules
ASM/
Description
communications
module
ASM 456
ASM 456 for PROFIBUS DP V1
max. 2 readers can be connected
ASM 475
ASM 475 for SIMATIC S7
max. 2 x RF2xxR readers with RS-422 can be connected at the same time
without front connector
RF120C
Communications module RF120C for SIMATIC S7-1200
RF160C
Communications module RF160C for PROFIBUS DP V0
max. 2 readers can be connected
RF170C
RF170C communications module
RF170C connecting block
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
IP67
Memory size: 2000 bytes of FRAM user memory
Operating temperature range: -25 °C ... +125 °C
Dimensions (Ø x H): 27 (±0.2) x 4 (±0.2) mm
IP68; IP x9K
Memory size: 2000 bytes of FRAM user memory
Operating temperature range: -25 °C ... +85 °C
Dimensions (Ø x H): 24 X 10 mm; M6 thread
Screw transponder
IP68
Memory size: 2000 bytes of FRAM user memory
Operating temperature range: -25 °C ... +85 °C
Dimensions (Ø x H): 50 x 3.6 mm
Round design with mounting hole
IP68; IP x9K
Memory size: 2000 bytes of FRAM user memory
Operating temperature range: -25 °C ... +85 °C
Dimensions (Ø x H): 18(±1) x 20(±1) mm (without thread); thread M8
IP68
Memory size: 2000 bytes of FRAM user memory
Operating temperature range: -25 °C ... +85 °C
Dimensions (Ø x H): 16 (±0.2) x 3.0 (±0.2) mm
Appendix
A.3 Ordering data
Article number
6GT2600-4AC00
6GT2600-4AG00
6GT2600-4AH00
6GT2600-4AK00
6GT2600-4AB00
Article number
6GT2002-0ED00
6GT2002-0GA10
6GT2002-0LA00
6GT2002-0EF00
6GT2002-0HD00
6GT2002-1HD00