RF200 system planning
4.2 Field data of transponders and readers
Table 4- 10
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D423
MDS D424
MDS D426
MDS D428
MDS D460
All dimensions in mm.
Table 4- 11
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D424
MDS D426
MDS D460
All dimensions in mm.
38
SIMATIC RF260R field data
Length of the
transmission window (L)
120
80
110
120
60
120
120
80
80
110
140
55
80
75
50
50
Filed data SIMATIC RF290R, with ANT D5
Length of the
transmission window (L)
320
300
320
320
300
320
320
320
300
320
320
300
320
300
Operating distance (S
)
a
2 ... 110
2 ... 80
2 ... 75
2 ... 80
2 ... 40
2 ... 120
2 ... 100
2 ... 75
2 ... 60
2 ... 65
2 ... 110
2 ... 40
2 ... 60
2 ... 70
2 ... 40
2 ... 40
Operating distance (S
)
a
0 ... 400
0 ... 200
0 ... 350
0 ... 400
0 ... 130
0 ... 350
0 ... 400
0 ... 300
0 ... 200
0 ... 300
0 ... 400
0 ... 200
0 ... 300
0 ... 120
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Limit distance (S
)
g
130
85
100
110
45
135
120
90
70
80
140
45
70
85
45
45
Limit distance (S
)
g
500
280
400
500
180
450
500
400
280
380
500
280
350
160