Display Elements Of The Rf290R Reader - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

5.6.4

Display elements of the RF290R reader

LED
PWR
ACT
PRE
ERR
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Meaning
flashing
CM mode:
Operating voltage present, reader not initialized or antenna switched off
permanently
CM mode:
lit
Operating voltage present, reader initialized and antenna switched on
PC mode:
Supply voltage applied
Communication on the data line
Presence of a transponder in the antenna field
CM mode:
flashing: The type of flashing corresponds to the error code in the table in the
section "Error codes". The optical error display is only reset if the
corresponding reset parameter ("option_1 = 2") is set (see product
information "SIMATIC RF200 command set
(http://support.automation.siemens.com/WW/view/en/44864850)").
PC mode:
permanently lit: Error when connecting the antenna or the interference level
in the antenna environment is too high
Readers
5.6 SIMATIC RF290R
109